Remote Operation
6.4 Common Commands
The following contains the common commands of SCPI that the Ethernet
controller is compatible with.
The possible error codes assume that the correct syntax is used and, in case of
a multiple command string the string is not too long.
If these conditions are not met, any given command can generate these error
codes: 3, 4, 30
6.4.1 *IDN?
Syntax
*IDN?
Result
A string is returned which consists of the following parts:
Model
Model Matrix model number
Possible error codes
None
Example
“*IDN?”
Result
“MS-2U18S-1/6T-ENET”